Analisa Beban Pendingin Ruangan AC Ruang Auditorium Gedung Pusat Lantai 7 Universitas PGRI Semarang
DOI:
https://doi.org/10.36706/jrm.v25i1.1379Keywords:
Auditorium Room, Cooling, Temperature, HumidityAbstract
The Auditorium Room on the 7th Floor of the Central Building at Universitas PGRI Semarang is frequently used for various academic and non-academic activities, making cooling load analysis essential to maintain room temperature and humidity comfort. This study aims to determine the cooling capacity required in the auditorium. The methods employed include direct data collection through measurements, such as the number of occupants, electronic equipment, and room dimensions. Cooling loads were calculated by considering sensible and latent loads; sensible loads were measured based on temperature and equipment quantity, while latent loads were calculated based on air humidity. This study identified the total cooling load for the Auditorium Room on the 7th floor of the Central Building at Universitas PGRI Semarang as 115,155.501 Btu/hr. This cooling load consists of 82,381.608 Btu/hr of sensible load and 32,773.893 Btu/hr of latent load. The cooling load includes various factors, such as: Internal loads from occupants, electronic equipment, and lighting. External loads from glass radiation, walls, floors, roofs, and ventilation. The analysis results indicate that the current AC capacity needs to be reassessed to ensure its capability to achieve ideal room temperature and humidity.
Downloads
References
Supriyadi, S., Farikhah, I., & Suhartono, S. Planning of air conditioner cooling load in the dean room of the faculty of engineering and information technology university of PGRI Semarang. Journal of Materials Exploration and Findings (JMEF), 1(1), 7. 2022.
Harahap, S., Hamid, A., & Hidayat, I. Perhitungan ulang beban pendinginan pada ruang auditorium gedung Manggala Wanabakti blok III Kementerian Kehutanan Jakarta. Progr. Stud. Tek. Mesin, Fak. Tek. Univ. Mercu Buana, Jakarta, 18(3), 149-154. 2014.
Ahyadi, H., Suprijatmono, D., & Pertiwi, T. B. Analisis Beban Pendingin pada Ruangan Data Center/Server PT X di Jakarta. 2022.
Aziz, A., & Mainil, R. I. Penggunaan Thermal Energy Storage sebagai Penyejuk Udara Ruangan dan Pemanas Air pada Residential Air Conditioning Hibrida. 2015.
Winarno, S. Analisa Perhitungan Beban Pendinginan Ruang Perangkat Internet di PT. X-Site Kedaton. Jurnal Teknik Mesin Mercu Buana, 8(3), 1-1711, pp. 1–14, 2014. 2017.
Anam, s. Analisis beban pendingin gedung kantor pt. Rga internasional lantai 5 di jakarta utara dengan ukuran 16m x 15m x 2, 8m. Ismetek, 12(01). 2021.
Rudoy, W., Cuba, J. F. Cooling and Heating Load Calculation Manual. Amerika Serikat: ASHRAE. 1979.
British Standards Institution. Building Materials and Products: Hygrothermal Properties: Tabulated Design Values. British Standards Institution. 2000.
Bake, M., Shukla, A., & Liu, S. Development of gypsum plasterboard embodied with microencapsulated phase change material for energy efficient buildings. Materials Science for Energy Technologies, 4, 166-176. 2021.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2025 Jurnal Rekayasa Mesin

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
Jurnal Rekayasa Mesin (JRM) memberikan akses terbuka terhadap siapapun agar informasi dan temuan pada artikel tersebut bermanfaat bagi semua orang. Semua konten artikel Jurnal ini dapat diakses dan diunduh secara gratis, tanpa dipungut biaya, sesuai dengan lisensi creative commons yang digunakan.