Pengaruh Jarak Sumber Jet Terhadap Temperatur Dinding Selinder

Authors

  • Kaprawi Jurusan Teknik Mesin Fakultas Teknik Unsri

DOI:

https://doi.org/10.36706/jrm.v9i2.15

Keywords:

orifice, jet flow, temperature, cilynder

Abstract

Free jet flow coming out from a rectangulaire orifice has temperature higher than than the ambient. This flow attack a cilynder so the wall temperature of cilynder will increase. The results show that the small temperature gradient at cilynder wall occur when the cilynder is palced far from the orifice. Near the orifice or jet source so great temperature gradient occur at the front wall of the cilynder. While at the back wall, starting from the separasion region, the temperature gradient is not high. The wider of orifice cross section the smaller temperature of waal cilynder.

Downloads

Download data is not yet available.

Published

2009-07-01

How to Cite

Kaprawi. (2009). Pengaruh Jarak Sumber Jet Terhadap Temperatur Dinding Selinder. Jurnal Rekayasa Mesin, 9(2), 045–049. https://doi.org/10.36706/jrm.v9i2.15